High Voltage DC Power Supply System YZPST-HVDC-720KW

High Voltage DC Power Supply System YZPST-HVDC-720KW HVDC series high voltage DC power supply system,nominal voltage240V/336V, with a maximum system capacity of 720kW, is a new type of high-frequency switching power supply equipment developed specil cally for IDCserver room IT, lt is a new type of high-frequency switching power supplyequipment developed for IDC server room lT equipment, adopting high-frequency soft-switching technology and modularized design switchingtechnology,modularized design, equipped with standard RS232/RS485 communication interface and network interface,adopts discrete cabinet structure,AC/DC power distribution in separate cabinets, suitable forcentralized power supply of medium and large IDCserver rooms,supercomputing centers,intelligent factories room,supercomputing center,intelligent factory, financial and other occasions.

Product Number:
INQUIRY
  • 产品描述
  •                                                                                                                                                                               High Voltage DC Power Supply System  YZPST-HVDC-720KW
    HVDC series high voltage DC power supply system,nominal voltage240V/336V, with a maximum system capacity of 720kW, is a new type of high-frequency switching power supply equipment developed specil cally for IDCserver room IT, lt is a new type of high-frequency switching power supplyequipment developed for IDC server room lT equipment, adopting high-frequency soft-switching technology and modularized design switchingtechnology,modularized design, equipped with standard RS232/RS485 communication interface and network interface,adopts discrete cabinet structure,AC/DC power distribution in separate cabinets, suitable forcentralized power supply of medium and large IDCserver rooms,supercomputing centers,intelligent factories room,supercomputing center,intelligent factory, financial and other occasions.
    Main Technical Indicators :
    > cross lnput voltage Dual supply 380v±30% (3 - phase 4 -wire + ground) .
    > Input frequency 50HZ±5HZ
    > output voltage 216v ~ 382v adjustable output
    > output current 20A ~ 1200A. (According to system design capacity)
    > Efficiency ≥ 95 % ·
    > voltage stabilization accuracy ≤0 . 5%
    > precision of current stabilization ≤ 1%
    > precision of current equalization ≤±5
    > Ripple coefficient ≤±0 . 5% Battery set 1 set
    > Battery group 1 group 4 groups (according to the capacity configuration)
    > Temperature range working: - 10℃ ~ +40℃ , storage: - 40℃ ~ +70
    > Relative humidity working: ≤90% (40℃±2℃) storage ≤95% (40℃±2℃) > Atitude ≤ 2000 meters
    Application scenarios:
    1 . Data center power supply system
    - Data centers have very high requirements on the stability and energy efficiency of power supply. Traditional AC Power supply requires multi -stage conversion (AC→DC→AC→DC) , with an efficiency loss of up to 15% - 20%.
    - HVDC Can directly provide DC Power (e. g. 380v DC) , which reduces the conversion process and improves the overall energy efficiency (the efficiency can be more than 95%) .
    utility + HVDC Direct supply: utility power is rectified to supply power directly to IT equipment, with batteries for seamless switching.
    - HVDC+photovoltaic/Energy storage system: combining renewable energy and energy storage to build a low- carbon power supply system.
    2 . communication base station power supply
    - communication base stations (such as 5G base stations) are mostly DC loads ( - 48v DC) , and the traditional program needs to convert AC mains to DC , which is inefficient and complicated.
    - HVDC Can directly output DC Power , simplifying the power supply link and reducing maintenance costs.
    - china Mobile , Huawei and other companies are piloting 240v/336v HVDC power supply system to replace the traditional -48V Dc program , which is suitable for 5G base stations with high power consumption.
    3 . Edge computing and microgrid
    - Edge data centers or remote communication sites need independent power supply, and HVDC Can be combined with photovoltaic and energy storage to build off-grid or hybrid power supply systems.

     

     